AC Not Blowing Air? Carrollton Homeowners’ Guide to Getting Cool Again


Heat and Air Gurus of carrollton tx pull up to a home in High Country subdivision for fall HVAC maintenance. Was this AC not blowing air? No way! not with Heat and Air Gurus taking care the furnace and AC.
Guru Technician pulling up to home in High Country subdivision of Carrollton, TX

If your AC isn’t blowing air, you’re not alone. Every summer in Carrollton, Texas, our phones ring nonstop with frustrated homeowners saying the same thing: “My AC runs, but there’s no air coming out!”

We get it — Texas heat doesn’t forgive, and when your home starts heating up, you need fast answers. This guide from Heat and Air Gurus will walk you through both DIY checks you can safely do and pro-level diagnostics we perform when your air conditioner stops blowing.

By the end, you’ll know what’s going on, what to look for, and when it’s time to “Call the Cow and Say WOW.”


Why “AC Not Blowing Air” Isn’t Just One Problem

When an air conditioner isn’t pushing air through the vents, it’s usually not random — it’s a symptom of airflow restriction or mechanical failure. Think of your HVAC system like lungs. If air can’t move in or out, comfort drops fast.

In Carrollton homes, the most common culprits are:

This is 3M Filtrete air filter is MERV 11 and getting plugged up. Some HVAC systems can not handle air filters that are this restrictive.
Some AC systems are NOT designed for 3M Filtrete

  • Dirty air filters

  • Frozen evaporator coils

  • Failed blower motor or fan capacitor

  • Dirty evaporator coil

  • Low refrigerant (causing freeze-ups)

  • Ductwork design or static pressure issues

Let’s break down each cause, how you can spot it, and what the Gurus do to fix it.


Dirty Air Filter — The #1 Culprit Behind Weak or No Airflow

Let’s start with the easiest fix. A clogged air filter is hands-down the most common reason an AC stops blowing air.

When your filter’s packed with dust and debris, airflow is choked off before it even reaches the blower. Here’s where it gets worse:

  • Low airflow causes the evaporator coil to get too cold.

  • Once it ices over, that frost becomes a solid wall of ice — no air can pass through.

  • Your system will run but not cool, and eventually, you’ll see water leaking when the ice melts.

DIY Tip:

  • Check your filter first. If it looks gray or furry, replace it.

  • Always install filters with the arrow pointing toward the furnace or air handler.

If your AC’s frozen, turn the system OFF and switch the fan to ON at the thermostat for 3–4 hours. This helps thaw the coil. Then call a Guru to inspect the cause before restarting cooling.

this Carrollton AC has a suction line (the large pipe with insulation) that is frozen up. The ice started at the evaporator coil inside and worked its way all the way outside. Almost to the greenbelt off Scott Mill
Look at the pipes on your Outdoor unit and check for ice.

Frozen Evaporator Coil — Why Ice = No Air

If you’ve ever looked inside your furnace or air handler and seen ice on the copper lines or coil, you’ve found the reason your AC isn’t blowing.

Ice acts like a barricade. Even if your blower motor is fine, air can’t move through a block of ice.

Common reasons for coil freeze-ups in Carrollton:

  • Dirty filters

  • Dirty coils restricting heat transfer

  • Low refrigerant levels

  • Poor duct design or undersized returns

Pro Insight: When our technicians see a frozen coil, we use gauges to check refrigerant pressure, test static pressure with a manometer, and verify temperature splits. We don’t just defrost it — we find why it froze so it doesn’t happen again.

Failed Blower Motor — The Silent Culprit

If your indoor blower motor fails, you’ll hear your outdoor unit running but feel no air inside.

The blower motor is what actually pushes cooled air through your ducts and vents. When it’s dead or struggling, airflow drops to zero.


Signs your blower motor has failed:

  • You hear a humming sound but no airflow

  • You smell a slight burning odor near the furnace

  • Breaker trips when the blower tries to start

  • Outdoor unit runs but vents blow nothing

There are two main blower types:

  • PSC (Permanent Split Capacitor) motors — common in older systems. They rely on a capacitor to start and can weaken over time.

  • ECM (Electronically Commutated Motor) motors — modern, variable-speed blowers that provide smoother airflow and efficiency but have electronic control modules that can fail.

DIY Tip: You can safely check for airflow by setting your thermostat fan to ON instead of AUTO. If you still get nothing, it’s likely the blower motor or capacitor.

At Heat and Air Gurus, we always show our customers live video from the blower compartment during inspection — so you know exactly what’s happening inside your system.

Close-up of A/C capacitors and a thermostat with Heat & Air Gurus logo. Text: "Empowers. Educates. Overdelivers. A/C Repair Carrollton."
Capacitors are one of the most common AC repairs we come across in North Dallas

Failed Blower Capacitor — Small Part, Big Problem

A weak or failed blower capacitor is a $10 part that causes $10,000 headaches.

This small metal cylinder stores and releases energy to start your motor. Without it, your blower can’t start up.

Symptoms:

  • Indoor unit hums but no air comes out

  • Motor sometimes starts after being off for a while, then quits again

  • You’ve had recent lightning storms or power surges

Capacitors wear out faster in Carrollton’s summer heat — especially if your furnace sits in a 130°F attic.

DIY Reality Check: Replacing a capacitor can be done by a qualified homeowner, but if you don’t have a meter or the right rating match, it’s better to call a Guru. Miswiring or using the wrong voltage capacitor can damage the motor or board instantly.


Dirty Evaporator Coil — When Dust Turns Into a Blanket

Your indoor evaporator coil is where the magic happens — warm indoor air passes over the coil, and refrigerant inside absorbs that heat.

But when the coil’s covered in dust, pet hair, or nicotine residue, air can’t pass through. The system strains, the coil gets colder, and soon it ices over — blocking airflow completely.

Common signs of a dirty coil:

  • Weak airflow at vents

  • Musty or sour smell from supply registers

  • High humidity in your home

  • AC runs nonstop but never feels cool

Pro Tip: Coils are delicate. We use a low-pressure coil cleaner and fin combs to restore proper airflow without bending fins. Once clean, we test temperature drop (ΔT) to confirm performance.

Dirty coils are often tied to poor filtration or duct leaks. So if it’s happening often, we’ll inspect your return side, filter fit, and attic ductwork design.

Heat and Air Gurus od Carrollton, uses the best Fluke meters and yellow jacket gauges to assure accuracy when checking your refrigerant
Zoom in! Can you tell if this unit is low?

Low Refrigerant — Invisible Problem, Real Consequences

Refrigerant isn’t like gasoline — it shouldn’t “run out.” If you’re low, there’s a leak somewhere. And when that happens, the system gets too cold and starts freezing.

Here’s how low refrigerant causes your AC to stop blowing air:

  1. Less refrigerant = lower pressure inside the coil.

  2. Coil gets below freezing point.

  3. Moisture in the air freezes on contact.

  4. Airflow slowly stops.

Symptoms:

  • Ice on refrigerant lines or coil

  • Hissing sound from outdoor unit

  • AC runs longer but rooms still warm

  • You’ve had to “top off” refrigerant before

Pro Technician Insight: At Heat and Air Gurus, we never just refill refrigerant and leave. We use electronic leak detection to pinpoint where it’s escaping — often from the evaporator coil, line set, or Schrader valve.

Once fixed, we weigh in the proper charge to match manufacturer specs. Running low refrigerant too long damages the compressor, and that’s a pricey replacement. Sometimes it may seem like the ac fan not blowing air, but actually the fan is running, and the air is being blocked by the ice.

Ductwork Design & Static Pressure — The Hidden Airflow Killer

Even if every part of your system is working perfectly, bad duct design can make it feel like your AC isn’t blowing air.

In many Carrollton homes, we find:

  • Undersized returns (not enough air getting back to the unit)

  • Too many restrictive 90° bends

  • Long duct runs with poor insulation

  • High static pressure readings (above 0.8" wc)

High static pressure means your blower is fighting to move air — like breathing through a straw. Not only does this cause poor cooling, but it also shortens blower and capacitor life.

Guru Insight: Whenever we install new equipment, we measure static pressure and redesign duct runs if needed. That’s why our replacements perform quietly and last longer.

DIY Note: If you’ve had multiple rooms that always feel hotter, ask for a duct design audit. Sometimes cutting in just one more return solves the problem permanently.


Other Uncommon But Possible Causes

While the major issues above cover 90% of “no air” situations, there are a few less common causes we see in the Carrollton area:

  • Blower door safety switch not engaged after filter changes

  • Clogged condensate drain triggering a float switch that shuts down the blower

  • Failed thermostat or control board miscommunicating with the fan

  • Collapsed flex duct in the attic due to poor routing or critters

Each of these can stop airflow in its tracks. Our technicians use diagnostic cameras and static probes to identify these hidden problems quickly.

DIY Homeowner Checklist Before Calling a Pro

If your AC isn’t blowing air in Carrollton, run through this checklist before scheduling a service call:

✅ Check your filter — replace if dirty.

✅ Make sure thermostat is set to Cool and Fan ON.

✅ Look for ice on the coil or copper lines.

✅ Check your condensate drain outside — is water flowing?

✅ Confirm your outdoor unit is running and not blocked by debris.

If everything checks out but you still have no air, you’re past the DIY stage — and it’s time for a Guru.


How Heat and Air Gurus Diagnose “AC Not Blowing Air”

When we arrive at a home in Carrollton, we don’t guess — we measure. Here’s what our diagnostic process looks like:

  1. Check static pressure to evaluate duct performance.

  2. Test capacitor and blower motor amperage.

  3. Inspect coil cleanliness and temperature drop.

  4. Check refrigerant charge and subcooling.

  5. Visually verify air movement and blower rotation.

  6. Show the homeowner video proof through our Guru Video Reports.

We want you to see what we see — no upsells, no mysteries, just transparency and solutions.


Why Carrollton AC Systems Freeze or Lose Airflow So Often

Carrollton homes face unique airflow stressors:

  • Attic-mounted furnaces in extreme heat

  • Long flex duct runs through hot attics

  • Dust and pollen levels that clog filters fast

  • Old duct systems not designed for modern variable-speed equipment

That’s why maintenance and static pressure testing are so crucial. Even the best AC can’t perform if it’s fighting airflow issues every cycle.


Stop the “AC Not Blowing Air” Cycle for Good

If you’ve had to thaw out your system or replace capacitors more than once, it’s time to go proactive. Our Prime Club and Wagyu Club memberships are designed for homeowners who want more comfort and fewer surprises.

Here’s what you get:

  • Two precision tune-ups per year (heating + cooling)

  • Static pressure testing to catch airflow issues early

  • Coil cleaning and drain treatment

  • Capacitor testing and replacement discounts

  • Priority scheduling during heat waves

  • Guru Video Reports emailed after each visit

Membership keeps your comfort consistent — and your repair costs predictable.